cisco12000_smWaveform Technology’s Michigan Data Center offers a total environment for your hardware and data. We occupy and operate our data center; we do not resell other provider's space. This keeps your equipment safe and Waveform's rates low. Always ask before selecting a colocation data center.

For more images of Waveform's Data Cetner, look here.

Waveform Built Michigan Fiber Optic Network

Connections are assured through redundant fiber paths leading to multiple upstream carriers.  We peer locally with our carriers, here in Southeast Michigan, and use combined layer-1 ring redundancy and layer-3 BGP4 IP protection to provide the Michigan Data Center with unparalleled uptime.  Waveform uses only Cisco routers and switches throughout our facility and network.

Because we’ve built Waveform's own Michigan fiber network, we offer reliable bandwidth at competitive prices.

Liebert Cooled Data Center

For cooling, we use nine redundant (n+1) Liebert Precision System/3 air conditioning units. These high capacity units are specificity constructed to cool a high density data center. A complete duct infrastructure covers the entire facility and ensures equal distribution of cool air. Servers produce a dry (or sensible) heat requiring each unit to also monitor and maintain a suitable humidity level, necessary to minimize static electricity.

Our Liebert air conditioning units are glycol cooled and utilize outdoor Liebert dry coolers for heat rejection. This setup allows us to take advantage of Liebert’s GLYCOOL system during cooler months. The GLYCOOL system routs the naturally cooled glycol returning from the dry coolers to a second coil inside each air conditioning unit, which becomes the primary source of cooling. This reduces or eliminated compressor run time and is an efficient data center cooling method—especially during Michigan’s winters.

For additional passive cooling redundancy, The Michigan Data Center's ceiling is a full 20 feet high. This allows equipment to radiate heat upwards instead of outwards towards neighboring servers.  Total heat rejection efficiency is higher.

Uninterruptible Power

In the event of a power outage, three Liebert online double conversion uninterruptible power supplies (zero transfer time) power the Michigan Data Center while a diesel generator starts. This setup provides disruption and distortion free electricity to our critical load. An indoor fuel tank can supply independent run time for a minimum of two days and priority refueling contracts through multiple vendors guarantee a constant supply. We test the generator weekly.

A+B+C bus power is available, meaning customers can request three independent power paths for their equipment, spanning three separate UPSs.

For the protection of customer equipment, a Liebert power surge suppression system guards the entire data center.

Constant Data Center Monitoring and Security by our Michigan Staff

A Pre-Action Dry Pipe fire suppression system protects against fire. The design couples advanced fire detection sensors with a dry pipe sprinkler system—providing security from false discharges without sacrificing safety.

An advanced security framework safeguards both the interior and exterior of the Michigan facility. We operate two independent digital video recording systems, covering the entire perimeter of the building, entrances, and secure sections inside the data center. Doorways are managed by a card access system which records all access. Security alarms elicit an armed response.

Our location in Troy, Michigan places our data center in a low crime area with a respected and professional Half and Quarter Racks in Waveform's Michigan Data Centerpolice force. Southeastern Michigan is also free from natural disasters such as hurricanes, floods, earthquakes, and tsunamis. The data center is above the 500 year flood plain.  Our staff monitors the data center 24 hours a day.

If you're local to Michigan, or sending your equipment across the country, Waveform's Michigan Data Center is a responsible choice for colocation.

 

 

Single Server Colocation

Waveform Technology is one of the few high end data centers to offer colocation for single servers.

More Michigan Data Center Information

Have a look at the Gallery, or Contact Us for a tour and see our data center yourself.

 

Rack Cabinet Colocation

Our Michigan Data Center offers private cabinets in a variety of sizes: